Dry-Eye Detector D600
Easily detect dry eyes and guide individual-based treatment proces
Technical Parameters
Light source Near infrared light source wavelength: 845nm
Blue wavelength: 455nm
Imaging resolution Color camera resolution: <50um
Near infrared enhanced camera resolution: <70um
Imaging mode White light imaging mode
Near infrared imaging mode
Blue light imaging mode
Clinical functions Tear meniscus height measurement
Analysis of tear film break-up time
Lipid layer analysis
Meibomian gland detection
Pinkeye analysis
Fluorescence image
Analysis of incomplete eye closure
Computer and printing system Hard disk: Capacity 2T
CPU: 17-8700
Graphics card: Intel 630 (128MB/ASROCK)
Memory: 16GB
Monitor: Philips 241E1W/93 (23.8 inches)
Efficient and accurate tear secretion
quality analysis
Measurement of non-invasive tear
meniscus height
Objectively evaluate the tear secretion amount and the
continuous state of tear meniscus, and complete the
examination quickly.
Optionally select 1-3 measuring points, output
average value to the accuracy of 0.01 mm, adopt
unique area amplification technology to reduce
the artificial measurement error and make the
measurement data more reliable.
Analysis of non-invasive tear film
break-up time
Objectively display the tear film break-up state without
traditional fluorescein sodium dyeing.
Objectively display the tear film break-up time
and area, and adopt the exclusive measurement
and error prevention technology, and provide
the mean tear film break-up time to accurately
evaluate the tear film break-up state.
Lipid layer analysis
Analyze the morphology and thickness of tear film lipid layer,
objectively reflect the secretion state of tear film lipid layer,
and conduct comprehensive diagnosis of MGD combined
with gland.
Use the principle of birefringence light interference
to quickly capture the image-text video of tear film
interference at moment of blink, and evaluate the
quality of lipid layer in classified manner as well as
evaluate the tear quality objectively and
comprehensively combined with tear meniscus
height and tear film break-up time.
HD meibomian gland shooting
Objectively evaluate the missing of meibomian
gland with clear image of gland shot under
comfortable infrared light.
Analyze the meibomian gland loss
and evaluate the severity in classified
manner.
Fluorescein dyeing analysis
Analyze the meibomian gland loss
and evaluate the severity in classified
manner.
Pinkeye analysis
Evaluate the degree of conjunctival
congestion in automatic and classified
manner and identify the potential case
of disease.
Analysis of incomplete eye closure
Apply exclusive patented technology for
HD blink tracking, quantitatively analyze
the incomplete eye closure.
ZD Medical Inc.
Tel:+86-571-8118-5697
Web: www.zdmedimage.com
Add.:3/F, No. 8 Building, No. 19 Jugong Rd. Binjiang District, Hangzhou, 310051 P.R. China
To learn more about ZD Medical Inc., please log on to official website of ZD Medical Inc.: www.zd-med.com / www.zdmedimage.com
* The CE registration of Dry-Eye Detector is in the process.We have right to modify the design and parameters without prior notice to you.
Compiled on: July 13, 2022